For some building users a self-closing fire door can become a barrier – or at least an obstacle which hampers their movement into and within the building.

Legislation aimed at providing universal accessibility in buildings requires service providers to make “reasonable adjustments to the physical features of their premises to overcome barriers to access”.

Approved Doc M of the Building Regulations and BS 8300 both provide guidance on determining the recommended maximum opening forces for door controls to assist less able users.

Opening v Closing Forces.

For accessibility, Approved Document M and BS 8300 are concerned with overcoming the resistance to opening which a door closer imparts. Both documents stipulate maximum “opening force” whereas for fire safety, EN 1154 is concerned with ensuring the door closes fully in order to maintain the door’s fire integrity and is measured as “closing moment” (a combination of the door’s mass and width). The two forces are not directly comparable.

Doors which need to be fire resisting and accessible must satisfy both the requirements of the maximum opening force for accessibility and minimum closing moment for fire safety. Non fire resisting doors only need to satisfy the maximum opening force requirements of BS 8300.

High-efficiency BOSS door closers are designed to meet the necessary standards for opening and closing forces. However, factors such as precise installation, hinge friction, door seals, and varying air pressure can all influence the opening resistance of the final doorset.

BS8300 Incorporating Amendment No.1 – 7.3.1 states:

"For disabled people to have independent access through single or double swing doors, the opening force, when measured at the leading edge of the door, should not be more than 30N from 0˚ (door in the closed position) to 30˚ open, and not more than 22.5N from 30˚ to 60˚ of the opening cycle."

"The ability of a controlled door closing device to close effectively while keeping within the opening force limits depends on its efficiency and the resistances from edge seals, hinge friction, latch resistance and differential air pressure. The opening force should be checked using a plunger type force measuring instrument."

Easy Opening, Reliable Closing.

Accessibility Guidance

To balance strict fire door closing requirements with accessibility, consider using electromagnetic hold-open, swing-free, or automated closers. These solutions minimise opening resistance, making doors easy to operate for all users, including children, the elderly, and people with disabilities.

Explore Our Solutions

Need help specifying inclusive door solutions for your project?

Contact us via the form below.

Name
name
true
form-fields-2col
text
+-.()#
Email
email
true
form-fields-2col
email
+-.()#
Phone
phone
true
form-fields-2col
tel
Company
company
true
form-fields-2col
text
Postcode
postcode
true
form-fields-2col
text
Products Interested In ?
products
form-fields-2col
text
Message
message
true
form-fields-1col